| Cat. No | Model | Parameter | Àü±Ø |
|---|---|---|---|
| P02-162-220 | S400 | pH/ mV/ ¡É | X (Æ÷ÇÔ ¾ÈµÊ) |
| P02-162-226 | S400-Kit | Expert Pro-ISM | |
| P02-162-230 | S400-Bio | Routine Pro-ISM | |
| P02-162-252 | S500 | pH/ mV/ Ion/ ¡É | X (Æ÷ÇÔ ¾ÈµÊ) |
| P02-162-256 | S500-Kit | Expert Pro-ISM | |
| P02-162-260 | S500-Bio | Routine Pro-ISM | |
| P02-162-264 | S500-F | PerfectION Fluoride | |
| P02-162-271 | S470 | pH/ mV/ Conductivity/ ¡É | X (Æ÷ÇÔ ¾ÈµÊ) |
| P02-162-275 | S470-Kit | Expert Pro-ISM, 731 | |
| P02-162-279 | S470-USP/EP | Routine Pro-ISM, 741 | |
| P02-162-299 | S475 | pH/ mV/ Ion/ Conductivity/ ¡É | X (Æ÷ÇÔ ¾ÈµÊ) |
| Model | Components |
|---|---|
| S400 |
Instrument, pH/mV Module, 2 Blank Module Electrode Holder, Cover, ¸Þ´º¾ó, Quick Guide, PC Software, Test Certificate
|
| S400-Kit | S400 ±¸¼ºÇ°, InLab Expert Pro-ISM 2 Buffer Sachets for pH 4.01, 7.00, 9.21 and 10.00 |
| S400-Bio | S400-Kit ±¸¼ºÇ°, ´Ü Àü±ØÀº InLab Routine Pro-ISM |
| S400-ISFET | S400-Kit ±¸¼ºÇ°, ´Ü Àü±ØÀº InLab 490 |
| S500 |
Instrument, pH/Ion Module, 2 Blank Module Electrode Holder, Cover, ¸Þ´º¾ó, Quick Guide, PC Software, Test Certificate
|
| S500-Kit | S500 ±¸¼ºÇ°, InLab Expert Pro-ISM 2 Buffer Sachets for pH 4.01, 7.00, 9.21 and 10.00 |
| S500-Bio | S500-Kit ±¸¼ºÇ°, ´Ü Àü±ØÀº InLab Routine Pro-ISM |
| S500-F | S500-Kit ±¸¼ºÇ°, ´Ü Àü±ØÀº Perfect Ion Fluoride |
| S470 | S400 ±¸¼ºÇ°, ´Ü Blank Module ´ë½Å Conductivity Module |
| S470-Kit | S470 ±¸¼ºÇ°, InLab Expert Pro-ISM, InLa 731-ISM 2 Buffer Sachets for pH 4.01, 7.00, 9.21 and 10.00 |
| S470-USP/EP | S470-Kit ±¸¼ºÇ°, ´Ü Àü±ØÀº InLab Pure Pro-ISM, InLab 741-ISM |
| S475 | S400 ±¸¼ºÇ°, Blank Module ´ë½Å Conductivity Module & pH/Ion Module |
| ±¸ºÐ | Measuring Range | Resolution | Accuracy |
|---|---|---|---|
| pH | -2.000 ~ 20.000 | 0.001, 0.01, 0.1 | ¡¾0.002 |
| mV (rel. mV) | -2000.0 ~ 2000.0 | 0.1, 1 | ¡¾0.1 |
| Temperature | -30 ~ 130¡É | 0.1¡É | ¡¾0.1¡É |
| Ion | - | - | - |
| Connector | pH (BNC), Temp (Cinch/RCA(NTC 30§Ú)), Stirrer(Mini-DIN) | ||
| Interface | Interface (RS232, USB-A, USB-B, LAN) | ||
| Power | DC 12V-10W | ||
| Size | w235¡¿d188¡¿h75 mm, 1120 g | ||
| ±¸ºÐ | Measuring Range | Resolution | Accuracy |
|---|---|---|---|
| pH | -2.000 ~ 20.000 | 0.001, 0.01, 0.1 | ¡¾0.002 |
| mV (rel. mV) | -2000.0 ~ 2000.0 | 0.1, 1 | ¡¾0.1 |
| Temperature | -30 ~ 130¡É | 0.1¡É | ¡¾0.1¡É |
| Ion | 0 ~ 999999 mg/L | 0.001 ~ 1 | ¡¾0.5% |
| Connector | pH (BNC), Temp (Cinch/RCA(NTC 30§Ú)), Stirrer(Mini-DIN) | ||
| Interface | Interface (RS232, USB-A, USB-B, LAN) | ||
| Power | DC 12V-10W | ||
| Size | w235¡¿d188¡¿h75 mm, 1120 g | ||
| ±¸ºÐ | Measuring Range | Resolution | Accuracy |
|---|---|---|---|
| pH | -2.000 ~ 20.000 | 0.001, 0.01, 0.1 | ¡¾0.002 |
| mV (rel. mV) | -2000.0 ~ 2000.0 | 0.1, 1 | ¡¾0.1 |
| Temperature | -30 ~ 130¡É | 0.1¡É | ¡¾0.1¡É |
| Ion | - | - | - |
| Conductivity | 0.001 uS/cm ~ 2000 mS/cm | 0.001 ~ 1 | ¡¾0.5% |
| TDS | 0.001 ~ 1000 g/L | 0.001 ~ 1 | ¡¾0.5% |
| Resistivity | 0.01 ~ 100.0 §Ú • cm | 0.01 ~ 0.1 | ¡¾0.5% |
| Salinity | 0.01 ~ 80.0 psu | 0.01 ~ 0.1 | ¡¾0.5% |
| Connector | Conductivity (Mini-DIN), Temp Seasor (Cinch/RCA(NTC 30§Ú)), Stirrer(Mini-DIN) | ||
| Interface | Interface (RS232, USB-A, USB-B, LAN) | ||
| Power | DC 12V-10W | ||
| Size | w235¡¿d188¡¿h75 mm, 1120 g | ||
| ±¸ºÐ | Measuring Range | Resolution | Accuracy |
|---|---|---|---|
| pH | -2.000 ~ 20.000 | 0.001, 0.01, 0.1 | ¡¾0.002 |
| mV (rel. mV) | -2000.0 ~ 2000.0 | 0.1, 1 | ¡¾0.1 |
| Temperature | -30 ~ 130¡É | 0.1¡É | ¡¾0.1¡É |
| Ion | - | - | - |
| Conductivity | 0.001 uS/cm ~ 2000 mS/cm | 0.001 ~ 1 | ¡¾0.5% |
| TDS | 0.001 ~ 1000 g/L | 0.001 ~ 1 | ¡¾0.5% |
| Resistivity | 0.01 ~ 100.0 §Ú • cm | 0.01 ~ 0.1 | ¡¾0.5% |
| Salinity | 0.01 ~ 80.0 psu | 0.01 ~ 0.1 | ¡¾0.5% |
| Connector | pH (BNC), Temp (Cinch/RCA(NTC 30§Ú)), Stirrer(Mini-DIN) | ||
| Interface | Interface (RS232, USB-A, USB-B, LAN) | ||
| Power | DC 12V-10W | ||
| Size | w235¡¿d188¡¿h75 mm, 1120 g | ||
| Cat. No | Model | Shaft | Description |
|---|---|---|---|
| P02-162-502 | InLab Expert Pro-ISM ¨ç | Peek | °¡È¤È¯°æ¿ë |
| P02-162-523 | InLab Routine Pro-ISM ¨è | Glass | ÀÏ¹Ý ½ÇÇè½Ç¿ë |
| Cat. No | Model | Shaft | Description |
|---|---|---|---|
| C19-162-522 | InLab 731 ¨é | Epoxy | 4 Graphite Pole |
| C19-162-542 | InLab 741 ¨ê | Steel | 2 Steel Pole |
| Cat. No. | Model | Description |
|---|---|---|
| P02-162-703 | 51344700 | Combined Silver/Sulfide Electrode |
| P02-162-707 | 51344703 | Combined Calcium Electrode |
| P02-162-711 | 51344706 | Combined Chloride Electrode |
| P02-162-715 | 51344709 | Combined Cyanide Electrode |
| P02-162-719 | 51344712 | Combined Cupric Electrode |
| P02-162-723 | 51344715 | Combined Fluoride Electrode |
| P02-162-727 | 51344718 | Combined Iodide Electrode |
| P02-162-731 | 51344721 | Combined Potassium Electrode |
| P02-162-735 | 51344724 | Combined Natrium Electrode / w S7 head |
| P02-162-739 | 51344727 | Combined Nitrate Electrode |
| P02-162-743 | 51344730 | Combined Lead Electrode |
| Cat. No. | Model | Description |
|---|---|---|
| C19-162-850 | 30034472 | PH/MV Expansion Unit |
| C19-162-860 | 30034473 | Conductivity Expansion Unit |
| C19-162-870 | 30034471 | PH/Ion Expansion Unit |
| C19-162-880 | 30034475 | Blank Expansion Unit |
| Cat. No. | Model | Description |
|---|---|---|
| C19-162-914 | 51302888 | Rondolino Sample Changer |